Micro-Z™ & Silver Conductive Garments

The Micro-Z Mini™ , Micro-Z II™ and Silver Conductive Garments offer a unique combination of support, enabling patients to have therapy where and when they need it. In the past, electrotherapy had been difficult to administer because of a lack of precision where to apply electrodes and loss of conductivity over time. Conductive Garments will deliver electrotherapy uniformly and consistently over the entire body part, providing deep-penetrating DC electric energy to the treatment area. Research supports that the micro-amperage delivered falls precisely within the narrow “biological waveband” of the body’s electromagnetic energy. Instead of merely masking pain, this micro-amperage electrochemically fuels the body’s natural healing mechanism, improving cell function, reducing edema, while increasing microcirculation aiding recovery from painful injuries or chronic disease. Using the copyrighted Micro-Z Mini™ software, patients select a treatment protocol and go about their business. Patient compliance and eagerness for treatment is quite high since the micro-stimulation delivered by the Micro-Z Mini™ is dosed below sensory. Our Conductive Garments are soft, comfortable to wear, washable, and are available in several forms such as gloves, sleeves, stockings, and can also be used with orthopedic bracing.

The World’s First Proprietary, Drug-Free Stimulation Garment System

• Reduces Pain Therapeutically • Improves Range of Motion
• Increases Microcirculation • Promotes Soft Tissue Healing
• Reduces Edema • Enhances Body’s Own Healing Process

FDA Clearance-510ks, ISO 1345 Certified

Recommended by the Agency for Healthcare Research and Quality (AHRQ) as an Adjunctive therapy for Wound Healing. • Over 75 Clinical Studies with HVPG waveform • Recommended by the Agency for Healthcare Research and Quality (AHRQ) as an Adjunctive therapy for Wound Healing

Acute & Chronic Pain

Effective For The Following Pain Conditions:

Leg, knee, & foot

• Peripheral Neuropathy
• Soft Tissue Injuries
• Phantom Limb Pain
• Wounds
• CRPS/RSD
• Edema

Hand & Arm

• Peripheral Neuropathy
• CRPS/RSD
• Carpal Tunnel
• Edema
• Arthritis
• Improve ROM
• Soft Tissue Injuries

Neck, back, & shoulder

• Soft Tissue Injuries
• Sciatica
• Herniated Discs
• Impingements
• Post Surgical Pain & Swelling

Chronic Wounds

Chronic Wound Healing • 50 years of clinical studies, A meta analysis of 95%
• Proof of clinical evidence rating of “A” by EPUAP and NPUAP 2009
• Micro-current shown to enhance fibroblast proliferation and re-epithelialization.
• Externally applied currents in the microampere range will attract growth factors and promote microcirculation-enhancing the body’s own healing mechanism.
• Clinical study demonstrating increased tissue perfusion in patients with diabetes and peripheral micro-vascular disease.
• Micro-current shown to increase capillary bed density in traumatized tissue.
• Up to 350% faster healing rates and stronger tensile strength of scar tissue formation.
• Pain and swelling reduced when micro-current is applied to traumatized tissue.
• Charged proteins are accelerated to lymphatic channels, hastening lymphatic reabsorption.

Therapy During the Day or While Sleeping…
Why Nocturnal Treatment?

The human body goes into a natural healing cycle when in a sleeping state.

  • 70% of growth hormones are produced during sleep.
  • Fibroblast cells are more active during sleep.
  • Micro-Z Mini™ promotes microcirculation while enhancing the body’s own healing process.

Microcurrent Electrotherapy

Microcurrent electrical stimulation more closely approximates the naturally occurring bio-electric current in the body. The current therefore is considered subsensory and cannot be felt. It provides "bio-stimulation" that stimulates cellular physiology and growth. It increases the adenosine triphosphate (ATP) generation, amino acid transport and protein synthesis. This causes the body to heal itself at a much faster rate.

It has long been known that all life processes involve electricity, and that biological processes can be affected by electrical treatment. The cells of the human body are basically tiny electrolytic batteries and microcurrents flow through the body in an orderly manner when there is no pathology present.

However, since injury disrupts the bio-electrical functions of the cells, the electrical activity of damaged cells is quite different from that of healthy ones. There is more electrical resistance in injured cells, so the normal energy flow through these cells is lower, impeding the healing processes and maintaining the presence of pain. If the electrical resistance of such injured cells can somehow be reduced, allowing the body's own electrical energy easy access to those cells, the health of the cells will improve. Inflammation may decrease, the healing process will be enhanced and pain can be lessened.

Traditional TENS versus Microcurrent Electrical stimulation

Traditional TENS

Micro-Z Microcurrent Therapy

“Blocks Pain”

“Therapeutically Mitigates Pain”

Stimulates the non-nociceptive large diameter nerve fibers, which blocks the pain coming from the nociceptive small diameter nerve fibers.

Small electrical charges can be helpful in initiating and perpetuating the numerous electrical chemical reactions in the healing process.

At the milliampere range, ATP generation was depleted, amino acid uptake was reduced up to 73% and protein synthesis was inhibited by as much as 50%.

At the microampere range, ATP generation increased about 500% and amino acid transport was increased by 30 to 40%.

Electricity will always take the path of least resistance. Traditional electrical charges placed on the body will travel around the traumatized cells.

A smaller current can penetrate the traumatized cells, balance the cell electrically, and can restore a more normal physiological state to those damaged cells.

Energy Load

Milliamps=slower ramp speed= poor skin penetration

Energy Load

Microamps=faster ramp speed= delivers current deeply through the tissues

Waveform

AC Current=biphasic=minimal potential on ion movement

Waveform

DC Current=monophasic=maximum potential on ion movement